Article
Last Month
Cable Bend Performance Minimum bending radius of each cable is provided in the catalogues for sensor controller. Refer to “Rated value/Performance [Cable/Peripheral devices]” in the catalogue. Cable name Type Minimum Bending Radius Camera cable FZ-VS3 FZ-VSB3 FZ-VSL3 FZ-VSLB3 69mm Long distance camera cable FZ-VS4 FZ-VSL4 78mm Encoder cable FH-VR 65
Settings backup for all lines in Multi-Line Random Trigger Mode If using firmware Ver.5.50, or later, settings data for all lines can be saved using the "Configuration copy" function. If using firmware Ver.5.32, or earlier, save the settings individually for each line Backing up Controller Settings All sensor controller settings can be backed up in
FH Simulation Software Installation Error If you are unable to install the Simulation Software, please check the following steps and take the appropriate measures. Verify ".NET Framework 3.5" is installed and install if necessary. To ensure there are no corrupt files in the install package, start from the first step of unzipping the installation zip
Saving Scene Variable Values If you wish to save Scene Variable values so that they will be saved even after doing a hardware power reset, when adding the variables, make sure to select the variable type with "(Save)" in the name. Refer to the following example. Example: When you wish to save an integer variable Set the variable type to "Integer (Sa
Restarting FH Controller There is a RESET signal for the Parallel Interface in the FZ Series, however there is not one for the FH Series. Procedure For the FH Series, use the Communications Command Macro if you need to restart the system over Parallel Interface. The method is as following: Use the SystemReset function. Enter the following for comman
Introduction It is possible to connect the touch panel monitor to multiple FHV7s. There is no limit for the number of FHV units you can simultaneously connect to. It depends on the specifications of the touch panel monitor because it depends on how many remote control tools can be active at the same time. Operation has been confirmed with up to 8 u
Introduction Application note for setting up a shared folder on a PC (Network Sharing) for an FHV7 camera. Required Equipment • Laptop (IP address 10.5.6.200) • FHV7 (IP address: 10.5.6.100) Note: For purpose of this application note default IP address are used for the FHV7 and it is assumed that personnel understand FH / FHV Programming / Setup /
Communication Command Macro Use the "MDI_SetDataBtn" Layout window component. From the [Layout modification] menu, select [Addition of window parts] and from the displayed list, select "MDI_SetDataBtn" to add it. Example "MDI_SetDataBtn" Parameter Setting Data Type System data Data Indentifier0macro_IO macro_IO Data Indentifier1 GOSUB Data *FUNC_000
Introduction How to create a connection using Ethernet/IP between NJ/NX PLC and a Microscan Barcode Reader (QX-870). Required Hardware and Software Hardware: • NJ/NX PLC and Power Supply • Device to be connected (QX-870) • Ethernet Switch/Router • PC • Ethernet Cables Software: • Sysmac Studio • Microscan ESP Files: • EDS file for the device to be c