E3AS-HF - Hysteresis Mode

Hysteresis Modes of the E3AS-HF

Written by Christopher Free

Updated at March 31st, 2026

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Products
    Automation Systems Control Components Motion & Drives Quality control & Inspection Robotics Safety Sensing Services Software Switching Components
  • Amplify e-Store
    e-Store public
  • Public CSC
+ More

This article outlines the Hysteresis Modes of the E3AS-HF Sensor.

The point at which the output turns from OFF to ON is called the operating point and the point at which it turns from ON to OFF is called the return point. The distance between the operating and return points is called hysteresis width. 

For this sensor, threshold value is equal to operating point, so the distance to the return point can be set by the hysteresis width. The definition of hysteresis width for each output mode is shown on the figure below

Single Point Mode

Window BGS Mode

Window FGS Mode

e3as hysteresis