Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
Gene-Robert

Gene-Robert Kenji

gene.kenji@omron.com

0

Article
Last Month

Gene-Robert articles

All Categories
  • All Categories
  • Products
  • Amplify e-Store
  • Public CSC

OMRON Product Discontinuation Information

Published May 6th, 2026 by Gene-Robert Kenji

When working with industrial automation systems, it’s important to stay informed about the lifecycle status of components. This article provides guidance on how to check whether an OMRON product has been discontinued and what steps to take next. Understanding Product Lifecycle Status OMRON products typically move through several lifecycle stages, in

1 min

Step by Step Guide - Microsoft SQL Server to OMRON N Series

Published March 4th, 2022 by Gene-Robert Kenji

Introduction This document will demonstrate how to connect an OMRON NX102-1020 (database model) PLC to a MS SQL Server database. It will show you how to get started with programming the OMRON NJ/NX Database CPU UNITS to: Configure, connect and disconnect to a MS SQL Server Database Add entries Read entries Update entries Delete entries Pre-Requisite

26 Views 5 min

Step by Step Guide - NA5 remote monitoring/operation via VNC

Published March 4th, 2022 by Gene-Robert Kenji

Introduction This guide will demonstrate how to setup your OMRON NA5 HMI for viewing and/or operation remotely with VNC (virtual network computing). This can be achieved with a local network connection or remotely via a modem. Pre-Requisites <add intercel modem relevant KB links> Further Reading <insert  OMRON NA User's Manual List of NA5 M

1138 Views 2 min

G9SP Configurator - Where to Download?

Published May 6th, 2026 by Gene-Robert Kenji

Introduction The G9SP Configurator is the software tool used to program, configure, and maintain the G9SP safety controller. This article provides guidance on where to download the software and what is required to access it. Download Location The G9SP Configurator can be downloaded from Omron’s official European industrial automation website: https:

1 min

CP1L-E Remote Connection with 3G/4G modem

Published April 7th, 2022 by Gene-Robert Kenji

Introduction This guide will show you how to configure the Omron CP1L-E for remote connection on a 3G/4G modem. Please refer to these Precautions and Terms and Conditions‍  which relate to the information and program samples provided before proceeding Procedure Network Setup Step 1 - PC Configuration Setup the PC so it has a static IP within the 192

384 Views 2 min

Step by Step Guide - Setting up a Scheduled Task to Automatically download log files from an NB screen via FTP

Published March 5th, 2022 by Gene-Robert Kenji

Introduction This guide demonstrates how to utilize Window’s built in FTP client to automatically download and delete files from the NB Screen’s FTP server via script and Windows Task Scheduler. Pre-Requisites OMRON NB Designer Knowledge Further Reading OMRON NB Designer Operations Manual Microsoft Windows FTP Command Reference Please refer to these

642 Views 2 min

G9SP Stuck in Idle Mode after Power Trip

Published May 6th, 2026 by Gene-Robert Kenji

Introduction A power interruption, such as a breaker trip, can sometimes leave a safety controller in an unexpected state upon restart. This article explains how to identify and resolve a condition where a G9SP safety PLC remains in Idle mode after power is restored. Reported Condition The issue typically presents with the following: A breaker trip

1 min

NS Runtime Connecting to CJ1M via Ethernet

Published May 6th, 2026 by Gene-Robert Kenji

Introduction This article provides a step-by-step guide for establishing communication between an NS Runtime Industrial PC (IPC) and a CJ1M PLC over Ethernet. It outlines the required configuration in CX-Designer and key setup considerations to ensure reliable connectivity. Pre-Requisites Before proceeding, ensure the following: The NS project has b

10 Views 1 min

Step by Step Guide: Microscan ID40 Barcode Reading to an NJ/NX PLC via Ethernet/IP

Published March 1st, 2022 by Gene-Robert Kenji

Introduction This guide will explain and demonstrate how to configure the Microscan ID40 barcode scanner to read, decode and store the barcode on the NJ/NX programmable logic controller. Please link any other KB articles or prior knowledge here which are referenced here Further Reading OMRON NX-Series EtherNet/IP Coupler Unit - User's Manual OMRON M

1253 Views 3 min

V+ Programming with Sysmac Global Variables

Published May 6th, 2026 by Gene-Robert Kenji

V+ Programming with Sysmac Global Variables Integrating robot control with PLC systems is a key requirement in modern automation. When using Omron robotics with the Sysmac platform, Global Variables provide an efficient way to exchange data between the PLC and robot programs. This article outlines how V+ programming can leverage Sysmac Global Variab

1 min

Can the OMRON TM use Modbus TCP Direct to NA5?

Published May 9th, 2023 by Gene-Robert Kenji

Scenario The OMRON TM is capable of Modbus TCP communications as both a server and a client.   The OMRON NA5 HMI has communication drivers for Ethernet, CIP Ethernet, FINS Ethernet and Modbus/TCP. However these are only specific to only OMRON PLCs and multi-axis controllers  The OMRON NA5 cannot communicate directly to an OMRON TM Collaborative Robo

731 Views 1 min

Step by Step Guide - Basic Setup of an OMRON NJ/NX OPC-UA Server

Published March 4th, 2022 by Gene-Robert Kenji

Introduction This guide aims to explain and demonstrate how to configure, view and change data tags remotely on the NJ/NX MAC via an OPC-UA client and 4G modem. Pre-Requisites OMRON Sysmac Studio knowledge Further Reading Where can I learn more about Sysmac Studio?‍ NJ/NX CPU Unit OPC UA User's Manual Intercel eSAM - Port Forwarding Manual Please re

1653 Views 3 min

Step by Step Guide - CP1L-E connection to an NS Screen via Ethernet/FINS

Published March 6th, 2022 by Gene-Robert Kenji

Introduction This document highlights the methods of: Configuring CP1L ethernet/FINS communications settings: 192.168.250.2 Configuring NS10 ethernet/FINS communications settings: 192.168.250.3 Setting a routing table to set both devices on the same network: #1 Pre-Requisites Note that each device has their own individual node id number. As seen in

766 Views 1 min

Step by Step Guide - NS Projects to NS Runtime for IPCs

Published March 15th, 2022 by Gene-Robert Kenji

Introduction This guide will demonstrate how to convert current NS projects into NS Runtime for IPCs Further Reading NS Runtime User's Manual myOmron Europe - How To Convert CX-Designer Projects Version 8.2 To 8.1 NS Series - CX-Designer v3.XX User's Manual Please refer to these Precautions and Terms and Conditions‍  which relate to the information

799 Views 4 min
Load More

Gene-Robert follows these articles

  • Step by Step Guide - Microsoft SQL Server to OMRON N Series
  • Step by Step Guide - NA5 remote monitoring/operation via VNC
  • CP1L-E Remote Connection with 3G/4G modem
  • Step by Step Guide - Setting up a Scheduled Task to Automatically download log files from an NB screen via FTP
  • Step by Step Guide: Microscan ID40 Barcode Reading to an NJ/NX PLC via Ethernet/IP
  • Can the OMRON TM use Modbus TCP Direct to NA5?
  • Step by Step Guide - Basic Setup of an OMRON NJ/NX OPC-UA Server
  • Step by Step Guide - CP1L-E connection to an NS Screen via Ethernet/FINS
  • Step by Step Guide - NS Projects to NS Runtime for IPCs

Member of Groups

Engineering

Definition by Author

0
0
Expand