Contact Us
If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.
chandan.khanal@omron.com
Article
Last Month
When user wants to replace 8 channel profinet input card with 4 channel, follow the procedure below. Open CX-Configurator FDT (Make sure you have a latest version)Open your configuration file. From the list of Remote IOs, select the one you want to replace Click in the I/O Module tab and you will see the list of I/Os present in the rack.Select the I
Introduction The purpose of this document is to demonstrate how to connect and configure IO-Link master ILM400 with NX PLCs. For testing, E3S-F1500 IOLink sensor is used. Prerequisites The programmer should have better understanding of Sysmac Studio and IO-Link technology Please refer to these Precautions and Terms and Conditions which relate to
Introduction The purpose of this document is to demonstrate how to configure NX safety PLC with NJ MAC and exchanged variables between safety controller and main controller Pre-Requisites The programmer should have very good understanding of Sysmac and Safety programming Further Reading EStop Configuration Safety Output Configuration Procedure Step1
Introduction The purpose of this document is to demonstrate how to connect and configure Estop using NX-SL3300 and NJ PLC. Pre-Requisites The programmer should have very good understanding of Sysmac Studio programming environment Further Reading Please refer to these Precautions and Terms and Conditions which relate to the information and program
Predictive maintenance is one of the key maintenance strategies when it comes to optimize the assets reliability. There are various strategies or mathematical tools that are used to achieve the results. One of the key and simple mathematical tool is Probability Density Function. Probability density functions (PDFs) are a critical tool for the manuf
We have created a Sysmac Studio project with code to operate an i4L robot with PLC instructions via ePLC Connect and how to exchange deta between a Machine Controller and robot via ePLC IO Please download from these links ePLC Connect program example : https://omronasiapacificptelt.box.com/s/927t1b8pelvts00navoghxcfyfgfe1jg ePLC IO program example :
Introduction The purpose of this document is to demonstrate how to connect and configure GS7A using NX-SL3300 and NJ/NX Controller. Pre-Requisites The programmer should have very good understanding of Sysmac Studio. Please follow this EStop Configuration for EStop configuration Further Reading Please refer to these Precautions and Terms and Conditi
The link to download the protocol macros for Modbus is here
Provided the variable may not be defined appropriately, can cause issue of missing HMI user defined variable every time the Sysmac Studio is open. This creates an issue in Global Variable table (highlighted in pink). This issue can be sorted by implementing following method. 1.Copy/pasting all global variables of NA to Excel. 2.Deleting all global v
The number of Omron Robots that can be controlled by an N series Machine Controller varies according to one of several limiting factors. To assess this for yourself and your application, you should consider the following upper limits which may come into effect, depending on the model of the Machine Controller you evaluate. We have created some guide